Portable complex for adjustment of spring pressure relief valve SPTE 10P
Purpose
For determining of start-to-open pressure of spring relief valves
equipped with a manual override. Adjusting of these products is
conducted without dismounting them from the worksite, with an option
to record results in electronic and paper form
Construction
■ the portable complex was designed for quick and easy use of the
equipment on-site
■ an all-purpose mounting bracket allows to use the device for different
threaded connections of a doubling machine coverage
■ tests may be performed on the pipeline under pressure and at a zero
pressure
■ equipped with high-precision pressure sensors for adjusting
Delivery set
■ mechanical module
■ S-shaped strain gage force sensor
■ rugged tablet PC
■ interface cable
■ adapter USB-COM MOXA UPort 1110
■ monochrome A4 laser printer
■ USB extension interface cable
■ mounting elements kit
■ shipping container
Advantages
■ indispensable by operation with flangeless valves (complex allows
to test the spring relief valves on a pipeline and there is no
necessity to “cut out” valves for next welding connection)
■ high accuracy of test results due to use of four interchangeable
pressure sensors with the accuracy class 0.25 as well as two
interchangeable force sensors with the accuracy class C3
■ low mass of the device makes it convenient to work in
hard-to-reach places
■ does not require connection to any power supply units during the
testing
Specifications
Parameters
|
Value
|
Usable range DN, mm
|
25...200
|
Maximum test pressure, MPa
|
25,0
|
Overall dimensions, mm
|
560х560х880
|
Weight (without tools, accessories and interchangeable parts), kg
|
13
|
The technical characteristics and the image of the equipment are for informational purposes only and can be changed according to the specifications of the customer